summary:
Used for measuring solid material to make up and down alarming widely used in
steel,foodstuff,fertilizer etc. without any adjustment.
parameter:
power:220V AC 50Hz
output connecting point capacity:220V 5A AC
testing plate state parameter:revolvating speed:8n/min
signal lasting time:1 — 5s
power:3W
material state: ≤30mm granularity
capacity:0.2g/cm³
material temp:normal≤90ºC
high temp:≤240ºC
container pres. Normal ≤0.6MPa
resisting pres≤1.0MPa
testing pole length: side equipping L=150~1400mm
top equipping L=800~2000mm
surrounding temp:-25 ~ 80ºC
surrounding humidity:≤80%
material humidity:not stick material
connecting :flange:DN80 JB/81—94
screw: G11/2 (outside)
model
and ramrk:
|
spec.&model |
content |
|
Temp.in use |
ULK— |
1 |
|
normal≤90ºC
|
|
2 |
|
High
temp≤240ºC
|
|
connecting |
|
|
A |
|
|
|
screw |
|
B |
|
|
|
lange |
|
position |
|
|
|
1 |
|
|
side |
|
2 |
|
|
top |
|
pres.in use |
|
|
|
|
P1 |
|
≤0.6MPa |
|
P2 |
|
≤1.0MPa |
|
length of testing pole |
|
|
|
|
|
L |
Specific length(mm) |
|
|
ULK |
□ |
□ |
□ |
□ |
□ |
|
theory:
Made up of testing and changing
structure to measure and control by flange or screw connecting container.switch
adopts revolvating transferring system.