summary:
A practical and
simply instrument widely used in petrol,chemistry,food etc.to measure medium
level ,especially for underground storing container.
parameter:
measuring scope:0
~ 4000m
output signal:4 ~
20mADC
indicating
precision:±10mm
medium density:≥0.79g/cm³
medium
conglutination:≤15mPa
·S
connecting level
material: 1Cr18Ni9Ti、1Cr18Ni9Ti
lined with PTFE
working
temperature:-40 ~ 120℃
pressure:1. 6MPa
position
temperature:-40 ~ 60℃
load impedance: 0
~ 550Ω(at
24VDC supplying )
supply
power: 24VDC;220VAC、50Hz(accomping
with steady power)
thread
connect: M20×1.5(inside)
connecting
flange:PN1.6 DN150 JB/T82.1-94(or as required)
requirement of
separating explode:separating explode dIIBT4 self-safe ibIIBT4
theory:
Made
up of level sensor and power changer.side equipment model is adding a measuring
container,the theory of measuring is the same as the above.